---------------------- Target Monitoring Tool ---------------------------
-------------------------------------------------------------------------

Important : This software is protected by Copyright and the information
contained herein is confidential. Distribution, reproduction as well as 
exploitation and transmission of its contents is not allowed except if 
expressly permitted. Infringments result in damage claims.
Copyright Wavecom S.A. (c) 1999 - 2003.
See our homepage: www.wavecom.com

The TARGET MONITORING TOOL and SERIAL LINK MANAGER programs are used to communicate
with a WISMO(TM)-based target (HAPC debug mode).

TARGET MONITORING TOOL allows the user to monitor and control the internal running.

TERMINAL EMULATOR is used to communicate via AT commands (if available) with a 
WISMO(TM)-based target.

To uninstall: Using Windows 'Control Panel', select the Add/Remove Programs icon.
From the list of installed applications select 'Wavecom Development ToolKit' and
proceed with the automated UnInstallShield procedures.


TARGET MONITORING TOOL : Version History
========================================
Version 2.7.6 (19 Oct 2005)

Fix:	
	- UMTS Watch Improvement (Tracker 1119)
	- The information displayed in the status bar for "Overwrite target buffer" is wrong and the tooltiptext does not appear for the OverWriteTargetBuffer button when the mouse cursor is placed over it. (Tracker 1282)
	- Memory not released when workspace is closed-fixed (Tracker 1304)	
	- Move the checkbox "Enable automatic Handchecking with the target" from Misc page to Startup page. (Tracker 1155)	
	- Replace MUSE & Open MMI references & graphics by Open AT. (Tracker 1483)

Version 2.7.5 (25 July 2005)

Enhancement:
	- Increase the maximum number of task and mail box from 32 to 64(Tracker 907)
Fix:	
	- Removed the error while exiting SELIMA (Tracker 816)
	- Change the string "Open MMI" by "Open AT" when getting information about Target (Tracker 1152)

Version 2.7.4 (9 June 2005)

Fix:
	- Changed the path of Report file of DevToolKit Installation from "p:\\_Share\\Totem\\Report_Install" to 
	  "U:\\projet\\tools\\OpenRW\\Install_Totem"(Tracker 1101)
    	- Fixed the problem of no RTK traces on x60 platform ( Tracker 989)
	- Fixed the problem of no RTk traces on replay bin file from Selima ( Tracker 990)
	- Added Auto Handchecking feature to synchronize between TMT (Target Monitoring Tool) and the WM software, 
	  to verify their compatibility(Tracker 967).
	- Added Font changing feature for Watches windows(Tracker 960).


Version 2.7.3 (17 Mar 2005)

Fix:
    	- Fixed the problem of conflict between the resource ID for Watch window and "View->Always on Top" menu item.
	- Fixed the problem of missing AMR watch panel and wrong level in case of Default GPRS-GSM-UMTS workspace.


Version 2.7.2 (17 Jan 2005)

New Feature:
    - Changes to DevToolkit installer to merge UMTS and GSM-GPRS environement for Dual-Mode stack development.

Fix:
    - Changes to DevToolkit installer to display Login name in report install file.
    - Fixed the problem of not displaying the data at every alternate time of issuing "Request RTK status" command or             "Request EEPROM logged errors" command.
    - Set the default time interval, for updating the chart of Memory window, to 5 seconds.

Version 2.7.1 (23 Dec 2004)

Fix:
    - Changes to DevToolkit installer for installation of MS Chart Control(MSCHRT20.OCX).        
    - Addressed problem of frozen TMT in case no Workspace is loaded and user opens the Memory Window.

Version 2.7.0 (10 Dec 2004)

New Feature:
    - Automatic Kernel Monitor feature implementation.
Enhancement:
    - Help updated and added new files. 

Version 2.6.2 (17 Sep 2004)

Enhancements:
    - Multiple selections in Mailboxes / Tasks are possible.
    - Help updated and included the missing files. 
Fix:
    - Inconsistent display in Mailboxes/Tasks made consistent.
    - Once user clicks on Target or Rem/Targ or Remote the list box will not scrolls to top
      and the user can select the next item without scrolling down the list box. 

Version 2.6.1 (01 Sep 2004)

Enhancements:
    - Display progress window while TMT is looking for a new version at start-up.
    - User can configure the location of server where latest version of TMT is available.
    - Help updated.
Fix:
    - Deletion of multiple objects possible.

Version 2.6.0 (05 Aug 2004)

New features:
    - Provided feature for performing endurance test using TMT. A new tab
      "File Properties" has been added to "Preferences->Settings" dialog box.

Version 2.5.0 (28 July 2004)

New features:
    - "Check for latest version of TMT on server" functionality (Set the options of 
       this feature in "preferences->settings>startup" tab page).
    - Client window positions will be saved for each workspace. 

Version 2.4.3.1 (1 July 2004)
Fix:
     - Tools path was not getting updated properly in TMT User Interface
      since the path values were hardcoded. The values are now read from 
      the registry.

Version 2.4.3 (8 march 2004)

New features:
     - "Always on top" functionality (See "View" menu).
     - "Disable traces scrolling autostop" checkbox (see "Preferences" menu, then
      "Settings" command and "Misc" thumb), permitting to disable automatic scroll 
      stop when too many traces are detected.




Version 2.4.2 (23 january 2004)
New features:
     - The "Write" dialog box in "Object" thumb has been reviewed to permit 
      object contents edition.
   
Enhancements:
     - Help updated.
   


Version 2.4.1 (18 december 2003)
Fixes :
     - Traces formatting : a supplementary blank space was inserted in traces,
       which made MEDOR was unable to postprocess them. Removed this blank space.
     - Time stamping in traces corrected (time stamp occured when not required
       and vice versa).


New features:
     - Objects can now be erased and written in target.
       Note : "Erase" does not delete objects inside target. "Write" makes TMT
       pass in non-overwritting mode. 
     - Scrolling in Traces windows is automatically stopped when a throughput 
       greater than 100 frames/second is detected. This avoids to block TMT's
       user interface.
     - "Get versions" command also features binary information (size, date and
       time). Similar information is also retrieved from archive file and 
       compared with target information. 


Enhancements:
     - Help updated.
     



Version 2.4 (28 november 2003)
Fixes :
     - Watch levels are now correctly enabled when opening a panel
       (and correctly disabled when closing all panels).

New features:
     - Addresses with an "@" are resolved in RTK traces (symbol name is 
       displayed instead of address).
     - Worskpace file full path name is displayed in status bar (with tooltip).
     - Watch description file ("MokaWatches.ini") updated .

Enhancements:
     - Symbol files ("s" or "s64k") load is much faster.
     - Trace client reviewed to enhance stability and display more precise
       information.




Version 2.3.8.1 (12 november 2003)
Fixes:
   - Licence file generation was impossible.
   - No more duplicate IDs in object list (see "Object" thumb).



Version 2.3.8.0 (7 november 2003)
Enhancements:
   - Capability to read all flash objects (see in "Object" thumb,
     click "Read" button in "All Objects" area). Objects are
     created in TMT's "Object" folder.
     
     
       


Version: 2.3.7.0 (22 september 2003)
Fixes:
   - Displays all symbols in RAM thumb.
   
   
Enhancements:
   - Increased worskspace load speed.
   - Do not compute again RAM symbols display when RAM thumb 
     is selected.
   - A dialog box displays the files loaded when loading a 
     workspace.





Version: 2.3.6.0 (9 september 2003)
Fixes:
   - Avoid target crash when changing a feature
   
   
Enhancements:
   - Backtraces are now displayed immediately.
     WARNING : This optimization makes worskspace load slower.
   - Made splash screen less intrusive.
   - Displays incorrect paths in "Tools" menu.





Version: 2.3.5.0 (14 august 2003)
Fixes:
   - Various fixes on particular cases in ADS backtraces.
   
  
New features:
   - In "Get Versions" dialog box, stack version number is compared to
     version label embedded in TMT's files archive. 



Version: 2.3.4.0 (4 august 2003)
Fixes:
   - Now supports symbol names up to 255 characters with ADS backtraces.



Version: 2.3.3.0 (19 june 2003)
Fixes:
   - Rewrote features handler, to handle correctly business features.

New features:
   - TMT now sends an INFO_INIT flow on startup.



Version: 2.3.2.0 (5 may 2003)
Fixes:
   - Fixed bugs on EEPROM windows : data are correctly displayed with  both CSN1 and normal views.
   - Handles correctly backtraces.axf file in archive file.
   - Fixed bug on diagnose tooltips display (still displayed after an "Autodetect").  

Enhancements:
   - No need for redistribuable dlls anymore

New features:
   - Introduced default workspace for UMTS.
   - Added capability to specify a range to display object list



Version: 2.3.1.0 (4 march 2003)
Fixes:
   - Fixed a bug on backtraces (some backtraces were not displayed).
   - Fixed Settings > Com refresh problem in serial Baud Rate.
   - Fixed INFO_EEPROM2 flow minor bugs.

Enhancements:
   - Updated help.

New features:
   - Introduced new icons in toolbars,
   - Handles INFO_MSG2 flows,
   - Writes versions numbers in dumpfiles headers,



Version: 2.3.0.0 (12 february 2003)
Fixes:
   - Avoids crash when ADS backtraces HAPC flows are ill-formed.
   - Fixed occasional crash when closing "Settings" dialog box.

Enhancements:
   - Updated help.

New features:
   - Displays EEPROM parameters in big-endian or little-endian order (see contextual menu in EEPROM client window).
   - Displays current PC serial port rate in status bar.
   - Displays stack and customer versions (if handled by target). See in menu "Commands", "Get Versions" option. 
   - Introduced limited access to features.